Installation & Operation Manual
Swimming Pool Heat Pump
Thank you very much for purchasing our product,please keep and read this manual carefully
before you install heat pump.

Advertisement

Table of Contents
loading

Summary of Contents for Sunrain YC-007TB1

  • Page 1 Installation & Operation Manual Swimming Pool Heat Pump Thank you very much for purchasing our product,please keep and read this manual carefully before you install heat pump.
  • Page 3 Packing List Name Qty. Remark Installation &Operation Manual Wire-controller Wire controller box and sponge pad (Will install on the heat pump shell) Wire-controller Cable Drain-pipe (2 m) Drain-pipe connector Rubber shock absorber Heat Pump Unit (The pipe connector has been installed on the machine) - 1 -...
  • Page 4: Table Of Contents

    Please keep installation manual properly, and read it carefully before using. The unit must be installed by professional personnel, and install it based on this manual as possible. Special reminding: if the unit would be installed where is vulnerable to lightning stroke, lightning protection measurements must be carried out.
  • Page 5: Accessories Description

    1. Accessories Description Each unit produced by our factory is with the following accessories: Name Qty. Installation & Operation Manual 1 PC Guide users to install the system Wire controller 1 PC Used for the man-machine operation interface Wire controller connecting cable 1 PC Connect wired controller to heat pump unit Drain-pipe...
  • Page 6: Attention For Safety

    2. Attention for safety Range of application: 1.Power supply: 230V/1N~50Hz. 2.Environment temperature: -7°C〜43°C : 3.Working water temperature: Min. inlet water temperature 8°C,Max. outlet Water Temperature 40°C. If the system is always used beyond the available water range, please contact with manufacturer. The installation shall be done by the professional persons, to prevent leaking, electric shock, or fire ●...
  • Page 7: Heat Pump Unit Working Principle

    Can not install the unit in combustible gas easy-leaking places, once the combustible gas leaks around ● the unit, it may cause a fire. Confirm if the installation base is strong enough, if it is not strong and has been used for a long time, it ●...
  • Page 8: Installation Of The Unit

    4. Installation of the unit 4.1 Installation attention ● Avoid installations in such locations with mineral oil. ● Avoid installation in locations where air contains salt or other corrosive gas. ● Avoid installation in locations with serious power supply voltage fluctuation. ●...
  • Page 9 4.4 Heat pump unit size Figure 3 Horizontal type heat pump size Size(mm) Model No. YC-007TB1 YC-010TB1 YC-012TB1 4.5 Reserve the installation base for the heat pump Please refer to Figure 4. A n c h o r b o lt...
  • Page 10: Installation Of The Pipeline

    ●Recheck whether the foundation is correct before hoisting the unit. ● The heat pump will produce condensation water,please consider the drainage channel when make the installation base. ●Please put shock absorb on base surface. Figure 5 Hoisting diagram 5. Installation of the pipeline 5.1 Attention ●...
  • Page 11 ●Regarding the installation of backup pump, maintenance valve and temperature measure point, please consider it yourself. ●All pipes and valves of the unit need the heat preservation. 5.2.3 Selection of the water pipes Model No. Inlet Outlet YC-007TB1 DN50 DN50 YC-010TB1 DN50 DN50 YC-012TB1...
  • Page 12: Installation Of Optional Accessories

    6. Installation of optional accessories 6.1 Selection of the water pump ●The circulation pump is needed for the system, the power port is prepared for the pump, (one phase) NOTE For the single phase pump, please check the circuitry diagram. ●The head of circulation pump = height difference between water level and main unit + total pipelines resistance (determined by the hydraulic calculation) + pressure loss of main unit (see the nameplate on heat pump ).
  • Page 13: Installation And Operation Of Electric Devices

    ● If the unit is not matching the power line, please supply specifications refer to provisions, wires connecting is not allowed. ●After all wiring construction is completed, please check it before switch on the power supply carefully. 7.2 Electrical Wiring Specification Model Electrical Wiring Specification YC-007TB1 3*2.5 mm² YC-010TB1 3*2.5 mm² YC-012TB1 3*2.5 mm²...
  • Page 14 NOTE: Here only for signal control never drive it directly Figure 11 Figure 12 - 12 -...
  • Page 15 7.4 Electric wiring diagram Figure 13 COMP : COMPRESSOR GND : GROUND AMBT: AMBIENT TEMPERATURE SENSOR WFS: WATER FLOW SWITCH LOW : LOW PRESSURE SWITCH HIGH : HIGH PRESSURE SWITCH COIL: EVAPORATOR COIL TEMPERATURE OWT/INWT: INLET / OUTLET WATER SENSOR TEMPERATURE SENSOR - 13 -...
  • Page 16: Instruction Of Operation

    8. Instruction of operation 1. Wire controller 1.1 Controller Instruction symbol status meaning Constantly bright heat pump is on Extinguished Heat pump is off Constantly bright at cooling mode Constantly bright at heating mode Constantly bright need repair Constantly bright at AUTO mode Extinguished Currently in the manual set temperature state...
  • Page 17 Flashing electric heater is on for disinfection Constantly bright current water temperature in the tank Constantly bright set water temperature in the tank Constantly bright current outlet water temperature Constantly bright current inlet water temperature Display actual water temperature, set water temperature and display fault code Constantly bright...
  • Page 18 1. Press at main interface to set the temperature. 2. Press and hold for 3 seconds in the power on/off state to enter the query state. 3. In the query status, press and check status 4. At parameter set status, press to modify parameters down 1.
  • Page 19 “ ”+“ ” Within 5 minutes after power-on, press and hold for 5 seconds to restore the factory parameter settings. +“ ”+“ ” 2. Operation Instruction 2.1 turn ON/OFF the heat pump When the controller is in the normal display state, press “ ”...
  • Page 20 clock interface, press the “ ” button, the hour part of the number flashes, press “∧” or “∨”, you can Set the hour of the clock; when the hour part is set, press the “Time” button again, the number of minutes will flash, press “∧”...
  • Page 21 "defrosting" operation is not allowed. 2.8 Query running status: When the main interface of the power on or off is displayed, press and hold the “∧” or “∨” button for more than 3 seconds to enter the running status query interface; press and immediately release the “∧” or “∨” button to check each operating condition;...
  • Page 22 When the water tank (inlet water) temperature ≥ the set temperature, the heating is stopped; Cooling mode: When the water tank (inlet water) temperature ≥ set temperature + return difference, the cooling starts; When the water tank (inlet water) temperature ≤ the set temperature, the cooling stops. 3.2 Circulating pump control (water circulation heat pump): When defrosting, water pump is forced to run.
  • Page 23 When the controller is in the normal display state, press and hold the “ ” button for 3 seconds to start or turn off the timed water return function; the “ ” icon lights up when it is turned on, and the “ ”...
  • Page 24 the compressor will be locked in the shutdown protection state. At this time, only the shutdown and restarting can unlock the compressor. 4.3 High exhaust temperature failure: After the compressor starts running for 1 minute, when the exhaust gas temperature is detected to be higher than or equal to the exhaust high temperature protection value by 110°C for 10 consecutive seconds, an high exhaust temperature alarm occurs and the compressor stops.
  • Page 25: Adjusting And Initial Operation

    water temperature) When the water tank or ambient temperature sensor are faulty, electric heating operation is not allowed. “11E”, “12E”, “13E” ", "14E", "15E", "17E", "18E", "19E". are correspondingly displayed when the coil temperature sensor, ambient temperature sensor, exhaust temperature sensor, inlet water temperature sensor/tank temperature sensor, absorb temperature sensor, and outlet water temperature sensor/return water temperature sensor are faulty.
  • Page 26: Operation And Maintenance

    ●Forced operation is forbidden, because it is very dangerous to work without protector. 9.2 Preparation Before Adjustment ●The system is installed correctly. ●Tubes and lines are putted in the right place. ●Accessories are installed. ●Ensure the smooth drainage. ●Ensure the perfect insulation. ●Correct connection of ground lead.
  • Page 27 hot water volume produced is less. We can adopt formic acid, citric acid, acetic acid or other organic acid to clean. ●The dirt retention on the surface of evaporator fin should be blew by more than 0.6Mpa compressor air, brushed by fine copper wire, or flushed by high pressurized water, usually one time per month; if too much dirt, we can use paintbrush dipping gasoline to clean.
  • Page 28: Fault Analysis And Elimination Method

    11. Fault analysis and elimination method - 26 -...
  • Page 29: Technical Parameter

    12. Technical parameter Model No. YC-007TB1 YC-010TB1 YC-012TB1 Power Supply 230V / 1/ 50 Hz 230V / 1/ 50 Hz 230V / 1/ 50 Hz Heating Capacity(kW) ¹ 12.5 10.0 Power Input(kW) ¹ 1.19 1.63 2.05 COP ¹ 6.05 6.13 6.10...
  • Page 30: After-Sale Service

    After-sale service If your hot water heater can not operate normally, please turn off the unit and cut off the power supply at once, then contact with our service center or technical department. - 28 -...

This manual is also suitable for:

Yc-010tb1Yc-012tb1